:: iPad Cases :: Pt Chart :: Share Case :: CME FAQs :: RSS COW feed :: Hide-close ::

Welcome! It's Thursday, May 23, 2013
:: :: ::

Click for :: Pt Chart :: Share Case :: Show Image :: CME FAQs

Close
Open-Close Option Buttons MedPix™Display: Image (16608)-Pt (6212)-Topic (3142)
| | | | | | | | | | | | :: Options-compass
MedPix™ Radiology Kiosk™ :: Search Icon Penetrating orbital trauma Topic ::Full-Screen Image :: Case Slide Sorter :: Export PowerPoint-
Translate
::
:: - RSS COW feed :: ::
Image Inventory :: Case Slide Sorter :: Patient Data


-Image Inventory-











:::::::::: ::
MedPix™:16608 - Penetrating orbital trauma
This Image has been re-sized to fit your screen
Click for Captions 16608
Image Contributor/Source: Les R Folio
::xray::Rewind to Figure 1   4 of 4   Fast Forward to Figure 4 - Edit::RAW | Case Slide Sorter
Axial :: CT - noncontrast :: Close Box

Use [Esc] to Show/Hide Caption ... [ SPACEBAR ] for Next Image
:: More like this? ( Penetrating orbital trauma ) :: :: :: ::
TITLE: Coronal CT through orbit

DESCRIPTION:
Note metallic fragment in right orbit with beam hardening artifact. Patient was in extreme pain, limited the exam, causing some movement and asymmetry. Concern about involvement of optic nerve since in center of orbit.

Note soft tissue swelling and irregular appearance just posterior to globe. Since no air or direct evidence of globe intrusion was demonstrated.


MedPix™ Image: 16608 :: Close Box
Uploaded by: Les R Folio ::
Submitted by: Les R Folio - Author Info
Case/Image Editor: James G. Smirniotopoulos, M.D. - Editor Info
Case Approved By: James G. Smirniotopoulos, M.D. - Editor Info
:: More like this? ( Penetrating orbital trauma ) :: :: :: ::

Use this  MedPix™ Visitor Feedback Form for Comments and Suggestions
MedPix™ has displayed more than   1,004,018,801   pages since 3 September 2000.