NOS - Not specified : BAS - Barium Swallow Achalasia - Read Topic

Dilation and tortuosity of the esophagus with retained food debris. The esophagus tapers smoothly distally prior to the GE junction. The LES fails to open during the exam. Occasional small jets of contrast were seen passing into the stomach.

ACR Code: 7 . 6

Original Source: Joseph J Probst
Submitted by: Joseph J Probst - Author Information
Affiliation: National Capital Consortium
Approved By: Albert V Porambo - Editor Information
Affiliation: National Capital Consortium

Click HERE to Learn About MedPix® COW Online CME/CNE



Use this MedPix® Visitor Feedback Form for Comments and Suggestions


MedPix® is sponsored by the Department of Radiology and Radiological Sciences, USUHS, Bethesda, MD
We do not accept paid advertisements.

This website is accredited by Health On the Net Foundation. Click to verify. We comply with the HONcode standard
for trustworthy health information:
verify here.


Text and Images may be Copyrighted © 1999 - 2009 by the Original Content Contributors.
Copyrighted materials are reproduced here with their Permission.

MedPix® is a Registered Trademark of USUHS :: The MedPix® Database Engine is Patented - USPTO No. 7,080,098
Portions of MedPix® are Copyright © 1999 - 2009 by J.G. Smirniotopoulos, M.D. & H. Irvine, M.D.
The MedPix® Classification Schema Copyright © 1999 - 2009 by J.G.Smirniotopoulos,M.D.
MedPix® has displayed more than   324,643,836   pages since 3 September 2000.

Database Successfully Disconnected